On-line monitors for single sampling.
It is an analyzer based on colour which controls and supervises hardness and chlorine in the water.
Every materials used for this analyzer have been produced to this and. A piston pump carries out a precise dosage. The meter chamber has been assembling inside of equipment and it has two rings. In this way there will not bacteria ‘s growth and maintenance will be very simple. The water and indicator consumption are reduced. It is perfect for utilities without control and /or maintenance staff.
Testomat 2000 THCL analyzer
Testomat 2000 THCL for Hardness and Chlorine (total) in the water
- titrometic analysis
- dosage by piston pomp
- display of result in various unit.
- programmable two high values which work in exit (high value 1 over passed, high over passed)
- programmable analysis range between 0 – 99 minutes
- possibility of volumetric analysis
- 6 release output : chlorine dioxide above the first programmable value, chlorine dioxide value above the second programmable value, washing, un working alarm, maintenance request e AUX to head a cooler.
- 4 input: stop analysis, start analysis, IN 1 zero-setting of water meter e IN 2 for a water meter
- documentation of analysis mistakes
- programmable supplementary program (for example: to start a cooler)
- address of programmable supporter
- galvanic division between voltage high side and low side
- within pressure regulator 0,1 – 8 bar
Order number:
Ord. Nr. | ||
Testomat 2000 THCL | 230V 50-60Hz, 0,1 – 8 bar 115V 50-60Hz, 0,1 – 8 bar 24V 50-60Hz, 0,1 – 8 bar |
200270 200280 200275 |
Accessories: | output 0 (4) – 20mA output RS 232 output 0/2 – 10 V cleaning set for road delivery cleaning set for air delivery SD card |
200300 200309 200308 200012 200012S 200207 |
Reagents for Testomat 2000 THCL (measuring chlorine):
Type | Contain | ppm Cl– | Ord.Nr. | |
Cl2250A Cl2250B Cl2250C |
500 ml 500 ml 500 ml |
0,0 – 2,5 | 200700 200705 200710 |
Or the complete set for chlorine
Type | Contain | ppm Cl– | Ord.Nr. | |
Set reagents | 500/300/200ml | 0,0 – 2,5 | 200711 |
For the water hardness (you have to take one of the following reagents):
°dH | °f | ppm CaCO3 | mmol/l | ||
TH2005 | 0,05 – 0,50 | 0,09 – 0,89 | 0,89 – 8,93 | 0 01 – 0,09 | 200690 |
TH2025 | 0,25 – 2,50 | 0,45 – 4,48 | 4,47 – 44,7 | 0,04 – 0,45 | 200691 |
TH 2100 | 1,0 – 10,0 | 1,79 – 17,9 | 17,9 – 179 | 0,18 – 1,79 | 200692 |
TH 2250 | 2,50 – 25,0 | 4,47 – 44,7 | 44,6 – 446 | 0,45 – 4,46 | 200693 |
Want to know more about the Testomat 2000 THCL analyzer?
Contact us for any information
Contact us