Testomat 2000 THCL analyzer

  1. Home
  2. Analyzer
  3. Testomat 2000 THCL analyzer

Testomat 2000 THCL for Hardness and Chlorine (total) in the water

On-line monitors for single sampling.
It is an analyzer based on colour which controls and supervises hardness and chlorine in the water.
Every materials used for this analyzer have been produced to this and. A piston pump carries out a precise dosage. The meter chamber has been assembling inside of equipment and it has two rings. In this way there will not bacteria ‘s growth and maintenance will be very simple. The water and indicator consumption are reduced. It is perfect for utilities without control and /or maintenance  staff.

  • titrometic analysis
  • dosage by piston pomp
  • display of result in various unit.
  • programmable two high values which work in exit (high value 1 over passed, high over passed)
  • programmable analysis range between 0 – 99 minutes
  • possibility of volumetric analysis
  • 6 release output : chlorine dioxide above the first programmable value, chlorine dioxide value above the second programmable value, washing, un working alarm, maintenance request e AUX to head a cooler.
  • 4 input: stop analysis, start analysis, IN 1 zero-setting of water meter e IN 2 for a water meter
  • documentation of analysis mistakes
  • programmable supplementary program (for example: to start a cooler)
  • address of programmable supporter
  • galvanic division between voltage high side and low side
  • within pressure regulator 0,1 – 8 bar

Order number:

Ord. Nr.
Testomat 2000 THCL 230V 50-60Hz, 0,1 – 8 bar
115V 50-60Hz, 0,1 – 8 bar
24V 50-60Hz, 0,1 – 8 bar
200270
200280
200275
Accessories: output 0 (4) – 20mA
output RS 232
output 0/2 – 10 V
cleaning set for road delivery
cleaning set for air delivery
SD card
200300
200309
200308
200012
200012S
200207

Reagents for Testomat 2000 THCL (measuring chlorine):

Type Contain ppm Cl Ord.Nr.
Cl2250A
Cl2250B
Cl2250C
500 ml
500 ml
500 ml
0,0 – 2,5 200700
200705
200710

Or the complete set for chlorine

Type Contain ppm Cl   Ord.Nr.
Set reagents 500/300/200ml 0,0 – 2,5 200711

For the water hardness (you have to take one of the following reagents):

°dH °f ppm CaCO3 mmol/l
TH2005 0,05 – 0,50 0,09 – 0,89 0,89 – 8,93 0 01 – 0,09 200690
TH2025 0,25 – 2,50 0,45 – 4,48 4,47 – 44,7 0,04 – 0,45 200691
TH 2100 1,0 – 10,0 1,79 – 17,9 17,9 – 179 0,18 – 1,79 200692
TH 2250 2,50 – 25,0 4,47 – 44,7 44,6 – 446 0,45 – 4,46 200693

Want to know more about the Testomat 2000 THCL analyzer?

Contact us for any information